Reference Guide

1402 | S-Series Stacking Commands
www.dell.com | support.dell.com
Command Modes
CONFIGURATION
Command
History
Usage
Information
Enabling this command keeps the failed switch in the failed state. It will not reboot until it is manually
rebooted. When enabled, it is not displayed in the running-config. When disabled, it is displayed in the
running-config.
Related
Commands
redundancy force-failover stack-unit
s
Force the backup unit in the stack to become the management unit.
Syntax
redundancy force-failover stack-unit
Defaults
Not enabled
Command Modes
EXEC Privilege
reset stack-unit
s
Reset any designated stack member except the management unit (master unit).
Syntax
reset stack-unit 0-7 hard
Parameters
Default
none
Command Modes
CONFIGURATION
Command
History
Usage
Information
Resetting the management unit is not allowed, and an error message will be displayed if you try to do
so. Resetting is a soft reboot, including flushing the forwarding tables.
Starting with FTOS 7.8.1.0, you can run this command directly on the stack standby unit (standby
master) to reset the standby. You cannot reset any other unit from the standby unit.
Version 8.3.1.0
Added the
all option
Version 7.7.1.0 Introduced on S-Series
show redundancy Display the current redundancy status.
0-7
Enter the stack member unit identifier of the stack member to reset.
hard
Reset the stack unit if the unit is in a problem state.
Version 8.3.1.0 Added hard reset option.
Version 7.8.1.0 Augmented to run on the standby unit in order to reset the standby unit directly.
Version 7.7.1.0 Introduced on S-Series