Reference Guide
120 | Control and Monitoring
www.dell.com | support.dell.com
Table 5-1 list the definitions of the fields shown in Figure 5-28.
Table 5-1. Descriptions for show linecard output
Field Description
Line card
Displays the line card slot number (only listed in
show linecard all
command output).
Status Displays the line card’s status.
Next Boot Displays whether the line card is to be brought online at the next system
reload.
Required Type Displays the line card type configured for the slot.
The Required Type and Current Type must match. Use the
linecard
command to reconfigure the line card type if they do not match.
Current Type Displays the line card type installed in the slot.
The Required Type and Current Type must match. Use the
linecard
command to reconfigure the line card type if they do not match.
Hardware Rev Displays the chip set revision.
Num Ports Displays the number of ports in the line card.
Up Time Displays the number of hours and minutes the card is online.
FTOS Version Displays the operating software version.
Jumbo Capable Displays Yes or No indicating if the line card can support Jumbo frames.
This field does not state whether the chassis is operating in EtherScale or
TeraScale mode.
Boot Flash Ver Displays the two possible Bootflash versions. The [Booted] keyword next
to the version states which version was used at system boot.
Memory Size List the memory of the line card processor.
Temperature Displays the temperature of the line card.
Minor alarm status if temperature is over 65° C.
Power Status Lists the type of power modules used in the chassis:
• AC = AC power supply
• DC = DC Power Entry Module (PEM)
Voltage Displays OK if the line voltage is within range.
Serial Number Displays the line card serial number.
Part Num Displays the line card part number.
Vendor ID Displays an internal code, which specifies the manufacturing vendor.
Date Code Displays the line card’s manufacturing date.