Reference Guide
1136 | Power over Ethernet (PoE)
www.dell.com | support.dell.com
Command Modes
CONFIGURATION
Command
History
Usage
Information
Setting a value above 320 causes a warning to be displayed that the device might lose power
redundancy.
power inline
c s
Enable power to be supplied to a device connected to a port.
Syntax
[no] power inline {auto [max_milliwatts] | static [max_milliwatts]}
To disable power to a port that has been enabled for PoE, use the no power inline command.
Parameters
Defaults
no (power is disabled to the port)
Command Modes
INTERFACE
Command
History
Usage
Information
Ports configured with power inline auto have a lower priority for access to power than those
configured with power inline static. As a second layer of priority setting, use the power inline
priority command.
FTOS treats powered devices rated as Class 0, 3, or 4 the same.
Related
Commands
power inline priority
c s
Set the PoE priority of the selected port.
Syntax
[no] power inline priority {critical | high | low}
Version 7.7.1.0 Introduced on S-Series
auto Enter the keyword auto to allow the port to determine how much power the
connected Class 0,1, 2, 3, or 4 device requires, and supply it (up to 15.4 watts).
max_milliwatts
(OPTIONAL) Enter the number of milliwatts to be the maximum amount of power
that a port can provide.
Range: 5000 to 15400 (milliwatts)
static Entering the keyword static without the max_milliwatts variable sets the amount
of power available on the selected port to the maximum (up to 15.4 watts).
Version 7.7.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series
power inline priority Set the PoE priority of the selected port.
show power inline Display the ports that are enabled with PoE and the amount of power that
each is consuming.