Configuration manual
1244 | E-Series ExaScale Debugging and Diagnostics
www.dell.com | support.dell.com
The PCDFO polling feature monitors data received over the switch fabric. When a DFO error is detected,
no automatic action is initiated by the system. The message issued is similar to the following.
Figure 63-10 illustrates the SFM architecture. Each ingress and egress FPTM maintaing ten (10) channels
connections to the ExaScale Switch Fabric.
Figure 63-10. E-Series ExaScale Switch Fabric Architecture
Respond to PCDFO events
Troubleshooting PCDFO events requires applying some human intelligence to differentiate between
transient and systematic failures. PCDFO events can be caused by several factors, including:
• Backplane noise
• Data corruption
Message 5 DFO Error Message
%RPM1-P:CP %CHMGR-2-SFM_PCDFO: PCDFO error detected for SFM4