1238 | E-Series ExaScale Debugging and Diagnostics
www.dell.com | support.dell.com
• If the loopback packet does not return to the CPU within 1 sec, another loopback packet sent out.
• Each loopback packet test failure appears in the
show trace linecard output.
• Additionally, a system message appears (Message 2).
• If both packets fail, a failed test result is sent to the internal FTOS task manager (TSM).
• Another test is initiated 45 seconds later.
• If the FTOS task manager (TSM) receives 3 consecutive failed messages (indicating 6 loopback tests
have failed), a syslog message appears indicating the port pipe with the failure.
• If the loopback packet does not come back, the system reads the CRC error values on S3, to determine
whether or not the SFM is bad. If the SFM is bad, the system reports CRC error as reason for SFM
problem state in the output of the show sfm command (Figure 63-1).
Figure 63-1. Sample output for SFM error
Message 2 Loopback test packet fail message
WAGT-(tsa):Rcvd TSM_SWAGT_X3_ALLCHN_LOOPBACK_REQ msg
Message 3 Consecutive failure syslog message
RPM0-P:CP %TSM-2-LP_LOOPBACK_FAIL: Linecard-SFM dataplane loopback test failed on linecard 1,
PP0: Fail, PP1: Fail
%RPM0-P:CP %TSM-2-SFM_ERR: Error detected in SFM 0 during loopback tests%
Force10#show sfm
Switch Fabric State: down (not enough working SFMs)
Switch Mode: SFM3
-- SFM card 0 --
Status : not present
-- SFM card 1 --
Status : card problem - Channel Error
Card Type : SFM3 - Switch Fabric Module
Up Time : 0 min
Last Restart : remote-off
Temperature : 34C
Power Status : PEM0: up PEM1: absent or down
Serial Number : 0064667
Part Number : 7520020001 Rev 03
Vendor Id : 04
Date Code : 01322006
Country Code : 01
FPGA : 0x0.0.3
Booting from : EEPROM0