Quick Start Manual
10 Installing the Hardware
Environmental Parameters
Power Supply
Width 17 inches (432 mm) 17 inches (432 mm)
Depth 16.73 inches (425 mm) 16.73 inches (425 mm)
Chassis weight with
factory-installed
components
12 pounds (5.5 kg) 12 pounds (5.5 kg)
Rack clearance required Front: 5-inches (12.7 cm)
Rear: 5-inches (12.7 cm)
Front: 5-inches (12.7 cm)
Rear: 5-inches (12.7 cm)
Parameter S2410P S2410CP
Temperature 32° to 104°F (0° to 40°C)
-40° to 158°F (-20° to 70°C)
32° to 104°F (0° to 40°C)
-40° to 158°F (-20° to 70°C)
Thermal Dissipation
(Maximum Thermal
Output)
S2410P: 768.2 BTU/Hour S2410CP: 426.8 BTU/Hour
Maximum altitude No performance degradation
to 10,000 feet (3,048 meters)
No performance degradation
to 10,000 feet (3,048 meters)
Relative humidity Operating: 10 to 90% relative
humidity (RH) non-
condensing
Storage: 10 to 95% RH non-
condensing
Operating: 10 to 90% relative
humidity (RH) non-
condensing
Storage: 10 to 95% RH non-
condensing
Shock MIL-STD-810 MIL-STD-810
Vibration Telcordia GR-63-CORE Telcordia GR-63-CORE
ISO 7779 A-weighted
sound pressure level
S2410P: 61.5 dBA at 73.4°F
(23°C)
S2410CP: 61.5 dBA at 73.4°F
(23°C)
Parameter S2410P S2410CP
Nominal Input Voltage 100 - 240 VAC, 50/60 Hz,
auto-sensing
100 - 240 VAC, 50/60 Hz,
auto-sensing
Parameter S2410P S2410CP