Quick Reference Guide
System Management Commands | 75
Serial Commands
This section describes the following SFTOS system management commands pertaining to console port
connections (serial connections, EIA-232):
• lineconfig on page 75
• serial baudrate on page 75
• serial timeout on page 76
• show serial on page 76
lineconfig
This command accesses the Line Config mode from the Global Config mode.
Syntax
lineconfig
Mode
Global Config
Usage
Information
Users executing this command enter the Line Config mode.
For details on modes, see Chapter 4, “Using the Command Line Interface,” on page 23.
Example
Figure 5-23. lineconfig Command Example
Related
Commands
serial baudrate
This command specifies the communication rate of the terminal interface. The supported rates are
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200.
Syntax
serial baudrate {1200 | 2400 | 4800 | 9600 | 19200 | 38400 | 57600 | 115200}
The no serial baudrate command sets the communication rate of the terminal interface to the 9600
default.
Default
9600
Mode
Line Config
(S50) #configure
(S50) (Config)#lineconfig
(S50) (Line)#
configure Accesses the Global Config mode, which is the mode in which you can execute this
lineconfig command.