Quick Reference Guide

GARP Commands | 259
set gmrp interfacemode all
Command
History
show gmrp configuration
This command displays GARP Multicast Registration Protocol information for one or all interfaces.
Syntax
show gmrp configuration {unit/slot/port | all}
Mode
Privileged Exec and User Exec
Example
Figure 15-91. Example of show gmrp configuration Command
Field
Descriptions
Interface—This displays the unit/slot/port of the interface that is described in this row of the
table.
Join Timer—Specifies the interval between the transmission of GARP PDUs registering (or
re-registering) membership for an attribute. Current attributes are a VLAN or multicast group. There is
an instance of this timer on a per-Port, per-GARP participant basis. Permissible values are 10 to 100
centiseconds (0.1 to 1.0 seconds). The factory default is 20 centiseconds (0.2 seconds). The finest
granularity of specification is 1 centisecond (0.01 seconds).
Leave Timer—Specifies the period of time to wait after receiving an unregister request for an attribute
before deleting the attribute. Current attributes are a VLAN or multicast group. This may be considered
a buffer time for another station to assert registration for the same attribute in order to maintain
uninterrupted service. There is an instance of this timer on a per-Port, per-GARP participant basis.
Permissible values are 20 to 600 centiseconds (0.2 to 6.0 seconds). The factory default is 60
centiseconds (0.6 seconds). The finest granularity of specification is 1 centisecond (0.01 seconds).
LeaveAll Timer—This Leave All Time controls how frequently LeaveAll PDUs are generated. A LeaveAll
PDU indicates that all registrations will shortly be deregistered. Participants will need to rejoin in order to
maintain registration. There is an instance of this timer on a per-Port, per-GARP participant basis. The
Leave All Period Timer is set to a random value in the range of LeaveAllTime to 1.5*LeaveAllTime.
Permissible values are 200 to 6000 centiseconds (2 to 60 seconds). The factory default is 1000
centiseconds (10 seconds). The finest granularity of specification is 1 centisecond (0.01 seconds).
Version 2.3
Changed to
gmrp interfacemode enable all.
Force10 #show gmrp configuration 1/0/1
Join Leave LeaveAll Port
Interface Timer Timer Timer GMRP Mode
(centisecs) (centisecs) (centisecs)
----------- ----------- ----------- ----------- -----------
1/0/1 20 60 1000 Disabled
Force10-S50 #show gmrp configuration all
Join Leave LeaveAll Port
Interface Timer Timer Timer GMRP Mode
(centisecs) (centisecs) (centisecs)
----------- ----------- ----------- ----------- -----------
1/0/1 20 60 1000 Disabled
1/0/2 20 60 1000 Disabled
1/0/3 20 60 1000 Disabled
1/0/4 20 60 1000 Disabled
1/0/5 20 60 1000 Disabled
1/0/6 20 60 1000 Disabled
1/0/7 20 60 1000 Disabled
1/0/8 20 60 1000 Disabled
!----------------output truncated---------------------!