Quick Reference Guide
Stacking Commands | 221
Interface—Stack port number (A or B)
Diagnostic Entry1—80 character string used for diagnostics.
Diagnostic Entry—80 character string used for diagnostics.
Diagnostic Entry3—80 character string used for diagnostics.
show switch
This command displays information about all units in the stack or about a specified unit.
Syntax
show switch [unit]
Mode
User Exec; Privileged Exec
Example 1
Figure 12-78 shows the output of both show switch and show switch unit-id for on an S50.
Figure 12-78. Example of Output from the show switch Command on an S50
Force10 #show switch ?
<cr> Press enter to execute the command.
<unit> Enter switch ID in the range of 1 to 8.
Force10-S50 #show switch
Management Preconfig Plugged-in Switch Code
Switch Status Model ID Model ID Status Version
------ ------------ ---------------- ---------------- --------------- --------
1 Mgmt Switch SA-01-GE-48T SA-01-GE-48T OK F2.5.1.0
Force10-S50 #show switch 1
Switch............................ 1
Management Status................. Management Switch
Hardware Management Preference.... Unassigned
Admin Management Preference....... Unassigned
Switch Type....................... 0x56950201
Preconfigured Model Identifier.... SA-01-GE-48T
Plugged-in Model Identifier....... SA-01-GE-48T
Switch Status..................... OK
Switch Description................ Force10 48 port Gigabit S50
Expected Code Type................ 0x100b000
Detected Code Version............. F.9.15
Detected Code in Flash............ F.9.15
Serial Number..................... DE4541040
Up Time........................... 0 days 0 hrs 26 mins 37 secs
Force10-S50 #show switch 8
Switch 8 does not exist!