Command Line Reference Guide

488 | Force10 Service Agent
www.dell.com | support.dell.com
Usage
Information
The Dell Force10 server associated with the default Dell Force10 Support recipient has a public key
that is shipped as part of FTOS, so you do not need to enter the key’s filename for that server. However,
if the Dell Force10 public key is changed, a notification will be made to download the new key from
the Dell Force10 website, and to replace the old key with that new key. Also, if you set up other
recipients, use this command to enter their key filenames.
On E-Series chassis, this command is only supported for TeraScale cards.
Related
Commands
log-messages
c e
This command collects information from the chassis.
Syntax
[no] log-messages [delay 60–1440] [severity 0–7] [filter word]
Parameters
Defaults
delay = 1440 minutes; severity = 7; filter = no
Command Modes
conf-callhome
Command
History
Usage
Information
Each of the three command parameters are optional and can be entered in any order, individually or in
combination.
The default severity level of 7 is the recommended severity level. Lower values will result in partial
log data sent to the server because messages with higher values are filtered out.
Related
Commands
Note: Execute the encrypt command after the keyadd command to ensure email encryption.
call-home Start FTSA and Enter the FTSA mode.
encrypt Enable email encryption.
server Configure recipients.
show keys Display the email encryption (PGP) keys.
delay 60–1440 (OPTIONAL) Enter the keyword delay followed by the number of minutes to delay
from the time of invoking the command after which
FTSA will accumulate system
log messages into a message.
severity 0–7 (OPTIONAL) Enter the keyword severity followed by the error severity level entered
in the system log that should be collected into the FTSA message.
filter word (OPTIONAL) Enter the keyword filter followed by a character string that FTSA should
use to search the system log. A search string containing spaces must be in quotes.
If the search yields a positive result, FTSA will send a log message with the string
included.
Version 7.7.1.0 Introduced on C-Series and E-Series
call-home Start FTSA and Enter the FTSA mode.
log-only Select the information collection action that matches the selected test group.
logging buffered Enable logging and specify which messages are logged to an internal buffer. By default,
all messages are logged to the internal buffer.
show logging Display the logging settings and system messages logged to the internal buffer of the
switch.