Command Line Reference Guide

802.1ah | 163
ethernet oam event-log size
s
Specify the size of the event log.
Syntax ethernet oam event-log size entries
Parameters
Defaults
50
Command Mode
CONFIGURATION
Command
History
ethernet oam link-monitor frame
s
Set the frame error thresholds and window.
Syntax ethernet oam link-monitor frame threshold {high {frames | none} | low frames
| window frames}
Parameters
Defaults
As above
Command Mode
INTERFACE
Command
History
entries Enter the number of entries for the log size.
Range: 0 to 200.
Default: 50.
Version 8.4.1.0 Introduced on S-Series
high {frames | none} Specify the high threshold value for frame errors, or disable the high threshold.
Range: 1-65535
Default: None
low frames Specify the low threshold for frame errors.
Range: 0-65535
Default: 1
window frames Specify the time period for frame errors per millisecond condition.
Range: 10-600 milliseconds
Default: 100 milliseconds
Version 8.4.1.0 Introduced on S-Series