Command Line Reference Guide
1476 | E-Series Debugging and Diagnostics
www.dell.com | support.dell.com
Total rate (bps) : 1634400
Total Size (bytes): 4086
Total Arp (bytes): 0
From 127.10.10.23:0 2128 bytes
From 127.10.10.23:9093 1500 bytes
From 127.10.10.11:4229 368 bytes
-- IRC Statistics --
irc phy: DOWN
-- Helios Statistics --
ACL Fpga Cp dataplane packets:9875 denied:0 dropped:0
ACL Fpga Rp1 dataplane packets:39125 denied:0 dropped:0
ACL Fpga Rp2 dataplane packets:274 denied:0 dropped:0
ACL Fpga Mgmt packets:19441 denied:0 dropped:0
FTOS#
show hardware btm
e
Display the Buffer Traffic Manager (BTM) error counters, status registers, or packet queue.
Syntax
show hardware {rpm | linecard} number port-set pipe-number btm {egress | ingress | all}
{errors | status | queues} {register starting-value [number_of_registers]}
Parameters
Defaults
No default behavior or values.
Command Modes
EXEC
EXEC Privilege
Command
History
Example FTOS#show hardware linecard 1 port-set 2 btm all errors
rpm Enter the keyword rpm to display RPM error counters, status registers, or packet
queue from the BTM.
linecard number Enter the keyword linecard followed by the line card slot number to display
BTM error counters, status registers, or packet queue on the specified line card.
Range: 0 to 13 on a E1200, 0 to 6 on a E600/E600i, and 0 to 5 on an E300
port-set pipe-number Enter the keyword port-set followed by the number of the line card’s Port-Pipe.
Range: 0 to 1
egress errors | status |
queues
(OPTIONAL) Enter the keywords egress errors, egress status, or egress
queues
to view egress BTM error counters, status registers, or packet queue.
ingress errors | status |
queues
(OPTIONAL) Enter the keywords
ingress errors, ingress status
,
or
ingress
queues
to view ingress BTM error counters, status registers, or packet queue.
all errors | status |
queues
(OPTIONAL) Enter the keywords all errors, all status, or all queues to view
all BTM error counters, status registers, or packet queue
register starting-value
[
number_of_registers]
Enter the keyword
register
followed by the starting value of the register to read from.
Range: 0 to 16777212
Optionally, enter the number of registers to read from. If no value is specified, only
one line is displayed.
Range: 1 to 512
Version 6.5.4.0 Introduced