Command Line Reference Guide
E-Series Debugging and Diagnostics | 1469
diag linecard
e
Run offline diagnostics on a line card(s).
Syntax
diag linecard number {alllevels | level0 | level1 | level2} | {terminate}
To terminate the offline diagnostics, use the diag linecard number terminate command.
Parameters
Defaults
All Levels (alllevels)
Command Modes
EXEC
EXEC Privilege
Command
History
offline
e
Place a line card in an offline state.
Syntax
offline {linecard number}
Parameters
Defaults
No default behavior or values.
Command Mode
EXEC
EXEC Privilege
Command
History
number
Enter the line card slot number.
Range: 0 to 13 on a E1200, 0 to 6 on a E600, and 0 to 5 on a E300.
alllevels Enter the keyword alllevels to run the complete offline diagnostic test.
level0 Enter the keyword level0 to check the device inventory and verify the existence of the devices.
level1 Enter the keyword Level1 to verify that the devices are accessible via the designated paths (line
integrity tests) and test the internal registers of the devices.
level2 Enter the keyword level2 to perform on-board loopback tests on various data paths (data
Port-Pipe and Ethernet).
terminate Enter the keyword terminate to stop the offline diagnostics tests.
Version 6.5.4.0 Introduced
linecard number Enter the keyword linecard followed by the line card slot number.
Range: 0 to 13 on a E1200, 0 to 6 on a E600, and 0 to 5 on a E300.