Command Line Reference Guide
E-Series ExaScale Debugging and Diagnostics | 1425
diag linecard
Not supported in FTOS version 8.1.1.0
e
x
Run offline diagnostics on a line card(s).
Syntax
diag linecard number {alllevels | level0 | level1 | level2} | {terminate}
To terminate the offline diagnostics, use the diag linecard number terminate command.
Parameters
Defaults
All Levels (alllevels)
Command Modes
EXEC
EXEC Privilege
Command
History
offline
Not supported in FTOS version 8.1.1.0
e
x
Place a line card in an offline state.
Syntax
offline {linecard number }
Parameters
Defaults
No default behavior or values
Command Mode
EXEC
EXEC Privilege
Command
History
number
Enter the line card slot number.
Range: 0 to 13 on a E1200, 0 to 6 on a E600, and 0 to 5 on a E300.
alllevels
Enter the keyword alllevels to run the complete offline diagnostic test.
level0
Enter the keyword level0 to check the device inventory and verify the existence of the devices.
level1
Enter the keyword
Level1 to verify that the devices are accessible via the designated paths (line
integrity tests) and test the internal registers of the devices.
level2
Enter the keyword
level2 to perform on-board loopback tests on various data paths (data
Port-Pipe and Ethernet).
terminate
Enter the keyword terminate to stop the offline diagnostics tests.
Version 8.1.1.2 Introduced on E-Series ExaScale E600i
Version 8.1.1.0 Introduced on E-Series ExaScale E1200i
linecard
number Enter the keyword linecard followed by the line card slot number.
Range: 0 to 13 on a E1200, 0 to 6 on a E600, and 0 to 5 on a E300.
Version 8.1.1.2 Introduced on E-Series ExaScale E600i
Version 8.1.1.0 Introduced on E-Series ExaScale E1200i