Command Line Reference Guide
sFlow | 1279
Usage
Information
The polling interval for an interface is the maximum number of seconds between successive samples of
counters to be sent to the collector. This command changes the global default counter polling (20 seconds)
interval. You can configure an interface to use a different polling interval.
Related
Commands
sflow polling-interval (Interface)
c e s
Set the sFlow polling interval at an interface (overrides the global-level setting.)
Syntax
sflow polling-interval interval value
To return to the default, use the no sflow polling-interval interval command.
Parameters
Defaults
The same value as the current global default counter polling interval
Command Modes
INTERFACE
Command
History
Usage
Information
This command sets the counter polling interval for an interface.
Related
Commands
sflow sample-rate (Global)
c e s
Change the global default sampling rate.
Syntax
sflow sample-rate value
To return to the default sampling rate, enter the no sflow sample-rate.
Parameters
sflow polling-interval (Interface) Set the polling interval for an interface
interval value
Enter the interval value in seconds.
Range: 15 to 86400 seconds
Default: The global counter polling interval
Version 8.2.1.0 Introduces on S-Series Stacking
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.7.1.0 Introduced on S-Series
Version 7.6.1.0 Introduced on C-Series
Version 6.2.1.1 Introduced on E-Series
sflow polling-interval (Global) Globally set the polling interval
value
Enter the sampling rate value.
Range: C-Series and S-Series: 256 to 8388608 packets
E-Series TeraScale and ExaScale: 2 to 8388608
Enter values in powers of 2 only, for example 4096, 8192, 16384 etc.
Default: 32768 packets