Command Line Reference Guide
Remote Monitoring (RMON) | 1189
Defaults
owner
Command Modes
CONFIGURATION
Command
History
show rmon
c e s
Display the RMON running status including the memory usage.
Syntax
show rmon
Defaults
No default behavior
Command Modes
EXEC
Command
History
Example FTOS# show rmon
RMON status
total memory used 218840 bytes.
ether statistics table: 8 entries, 4608 bytes
ether history table: 8 entries, 6000 bytes
alarm table: 390 entries, 102960 bytes
high-capacity alarm table: 5 entries, 1680 bytes
event table: 500 entries, 206000 bytes
log table: 2 entries, 552 bytes
FTOS#
absolute Enter the keyword absolute to test each MIB variable directly. This is the
alarmSampleType in the RMON Alarm table.
rising-threshold value
event-number
Enter the keyword rising-threshold followed by the value (64 bit) the
rising-threshold alarm is either triggered or reset. Then enter the event-number to
trigger when the rising threshold exceeds its limit. This value is the same as the
alarmRisingEventIndex or alarmTable of the RMON MIB. If there is no
corresponding rising-threshold event, the value is zero.
falling-threshold value
event-number
Enter the keyword falling-threshold followed by the value (64 bit) the
falling-threshold alarm is either triggered or reset. Then enter the event-number to
trigger when the falling threshold exceeds its limit. This value is the same as the
alarmFallingEventIndex or the alarmTable of the RMON MIB. If there is no
corresponding falling-threshold event, the value is zero.
owner string
(OPTIONAL) Enter the keyword
owner
followed the owner name to specify an owner
for the alarm. This is the alarmOwner object in the alarmTable of the RMON MIB.
Version 7.6.1.0 Support added for S-Series
Version 7.5.1.0 Support added for C-Series
Version 6.1.1.0 Introduced for E-Series
Version 7.6.1.0 Support added for S-Series
Version 7.5.1.0 Support added for C-Series
Version 6.1.1.0 Introduced for E-Series