Command Line Reference Guide
112 | Control and Monitoring
www.dell.com | support.dell.com
Usage
Information
The following example shows the output of the show environment fan command as it appears prior to
FTOS 7.8.1.0.
Example 1
(show
environment all)
FTOS#show environment all
-- Fan Status --
---------------------------------------------------------------------------
Unit TrayStatus Fan0 Fan1 Fan2 Fan3 Fan4 Fan5
0 up up up up up up up
-- Power Supplies --
Unit Bay Status Type
---------------------------------------------------------------------------
0 0 up AC
0 1 absent
-- Unit Environment Status --
Unit Status Temp Voltage
---------------------------------------------------------------------------
0* online 50C ok
* Management Unit
-- Fan Status --
Unit Status Speed Fan1 Fan2 Fan3 Fan4 Fan5 Fan6 Serial Num Version
---------------------------------------------------------------------------
1 up high up up up up up up 1234 1
Example 2
(show
environment fan)
FTOS#show environment fan
-- Fan Status --
---------------------------------------------------------------------------
Unit TrayStatus Fan0 Fan1 Fan2 Fan3 Fan4 Fan5
0 up up up up up up up
Example 3
(show
environment
pem)
FTOS#show environment pem
-- Power Supplies --
Unit Bay Status Type
---------------------------------------------------------------------------
0 0 up AC
0 1 absent
Example 4
(show
environment
stack-unit)
FTOS#show environment stack-unit 0
-- Unit Environment Status --
Unit Status Temp Voltage
---------------------------------------------------------------------------
0* online 49C ok
* Management Unit