Command Line Reference Guide

Control and Monitoring | 101
Defaults
Disabled.
Command Modes
EXEC Privilege
Command
History
Usage
Information
The command reset without any options is a soft reset, which means FTOS boots the line card from its
runtime image. The hard option reloads the FTOS image on the line card. Use the power-cycle after
upgrading an FPGA.
When a soft reset is issued on a line card (reset linecard number), FTOS boots the line card from its
runtime image. Only when you enter reset linecard number hard is the software image reloaded on
the line card.
Related
Commands
rpm <slot> location-led
e
x
Toggle the location LED on/off on the E-Series ExaScale RPM (LC-EH-RPM).
Syntax
rpm slot number location-led [on | off]
Parameters
Defaults
OFF
Command Modes
EXEC
Command
History
Usage
Information
The LED setting is not saved through power cycles.
sfm slot
number
Enter the keyword sfm followed by the failed or powered-off SFM slot number.
Note: Supported on E-Series only
Version 7.5.1.0 Introduced on C-Series
E-Series original Command
reload Reboots the system.
restore fpga-image Copy the backup C-Series FPGA image to the primary FPGA image.
rpm slot number
Enter the slot number
E1200i: 0-13
E600i: 0-6
on |off
Toggles the LED on the RPM on or off.
Version 8.2.1.0 Introduced on the E-Series ExaScale