Adjust the OAMPDU Transmission Parameters
Link Performance Event Monitoring
Link Performance Event Monitoring OAM monitors the receive side of a link for a set of pre-defined
errors and executes an action when a threshold is exceeded; it is enabled by default. Both peers on the link
must be have link performance event monitoring enabled for discovery to complete.
There is a high and low threshold for each pre-defined error; an event occurs when any threshold is
exceeded. FTOS periodically polls hardware registers for the current frame and symbol error count. If an
interface exceeds a threshold, a notification is sent to the peer and the interface is placed in error-disabled
state.
Enable Error Monitoring
Execute an Action upon Exceeding the High Threshold
Display Link Layer OAM sessions. show ethernet oam summary EXEC Privilege
FTOS# show ethernet oam summary
Output format :
Symbols:* - Master Loopback State, # - Slave Loopback State
Capability codes:L - Link Monitor, R - Remote Loopback
U - Unidirection,V - Variable Retrieval
LocalRemote
InterfaceMAC AddressOUIModeCapability
Gi6/1/10023.84ac.b8000000DactiveL R
Task Command Syntax Command Mode
Specify a the maximum or minimum
number of OAMPDUs to be sent per
second.
ethernet oam [max-rate value | min-rate value]
Range: 1-10
Default: 10
INTERFACE
Set the transmission mode to active or
passive.
ethernet oam mode {active | passive}
Default: Active
INTERFACE
Specify the amount of time that the
system waits to receive an OAMPDU
from a peer before considering it
non-operational.
ethernet oam timeout value
Range: 2-30 seconds
Default: 5 seconds
INTERFACE
Task Command Syntax Command Mode