Reference Guide
sFlow | 915
The configuration shown in the example in Show sFlow Globally is also displayed in the running
configuration:
FTOS#show running-config interface gigabitethernet 1/16
!
interface GigabitEthernet 1/16
no ip address
mtu 9252
ip mtu 9234
switchport
sflow enable
sflow sample-rate 8192
no shutdown
Show sFlow on a Line Card
Use the following command to view sFlow statistitics on a specified line card:
The following example is a sample output from the
show sflow linecard command:
FTOS#show sflow linecard 1
Linecard 1
Samples rcvd from h/w :165
Samples dropped for sub-sampling :69
Total UDP packets exported :77
UDP packets exported via RPM :77
UDP packets dropped :
Configure Collectors
The sflow collector command allows you to configure sFlow Collectors to which sFlow datagrams are
forwarded. You can configure up to two sFlow collectors (IPv4 or IPv6). If you configure two collectors,
traffic samples are sent to both devices.
sFlow collection through the Management interface is supported on platform: e.
IPv6 sFlow collectors and agents are supported only on platform:
e
x
.
Command Syntax Command Mode Purpose
show sflow linecard slot-number EXEC Display sFlow configuration information and statistics on the
specified interface.
Command Syntax Command Mode Usage
sflow collector {ipv4-address | ipv6-address}
agent-addr {ipv4-address | ipv6-address} [number
[
max-datagram-size number] ] |
[
max-datagram-size number ]
CONFIGURATION Configure sFlow collectors to which
sFlow datagrams are forwarded.
Default UDP port: 6343
Default max-datagram-size: 1400