Reference Guide

Force10 Service Agent | 349
Set the Frequency of FTSA Type 3 Messages
When messaging is enabled, FTSA sends an E-mail every 24 hours containing inventory information to all
recipients. There is no facility for setting the frequency for individual recipients.
Generate FTSA Type 4 Messages
FTSA can collect and E-mail a user-defined subset of the local system log.These E-mails are Type 4, and
Type 4 messages are enabled by default:
After the initial message, subsequent messages only include log entries with that were generated after the
last message was sent to the server so that log messages are not repeated in multiple E-mails.
Set Parameters FTSA Type 5 Messages
FTSA Type 5 messages have two configurable parameters:
Task Command Command Mode
Set the frequency at which FTSA generates inventory E-mails.
Range: 2 to 10080 minutes
Default: 1440 minutes (24 hours)
frequency minutes CALLHOME
Step Task Command Command Mode
1 Ensure that system logging is on, and verify the
logging severity level.
logging on
do show running-config logging
CONFIGURATION
2 Collect and E-mail system log messages.
If you do not use the severity option, FTSA
uses 7 by default.
This is the recommended severity level.
Lower values will result in partial log data
sent to the server because messages with
higher values are filtered out.
log-messages [delay minutes]
[severity level] [filter string]
CONFIGURATION
<SERVER>
Task Command Command Mode
Divert Type 5 messages to the internal flash
directory /CALL-HOME-LOGS instead of sending
them to FTSA recipients. Filenames include the
action list name and a timestamp, and use the file
extension .ftsa.
log-only
CALLHOME ACTIONLIST
All E-mails are generated in XML format by
default. For Type 5 messages only, you may
generate E-mails in clear text format. The
configuration is per action list.
message-format {xml | text} CALLHOME ACTIONLIST