Reference Guide
E-Series ExaScale Debugging and Diagnostics | 1123
FTOS#show linecard
-- Line card 0 --
Status : card problem - unsupported line card config(CAM size)
Next Boot : online
Required Type : E90MH - 90-port 10/100/1000Base-T line card with mini RJ-21 interfaces
10M CAM (EH)
Current Type : E90MH - 90-port 10/100/1000Base-T line card with mini RJ-21 interfaces
10M CAM (EH)
Hardware Rev : Base - PP0 - PP1 -
Num Ports : 90
Up Time : 0 sec
FTOS Version :
Jumbo Capable : yes
Boot Flash : A: 2.9.1.0 B: 2.9.1.0 [booted]
Memory Size :
Temperature : 55C
Power Status : PEM0: up PEM1: absent or down
Voltage : ok
Serial Number :
Part Number : Rev
Vendor Id :
Date Code :
Country Code :
Piece Part ID : N/A
PPID Revision : N/A
Service Tag : N/A
Expr Svc Code : N/A
Last Restart : hard reset by rpm
--- output truncated ---
Hardware watchdog timer
The hardware watchdog command automatically reboots an FTOS system with a single RPM that is
unresponsive. This is a last resort mechanism intended to prevent a manual power cycle.
Warm upgrade hard reset by rpm
Power-off/on the linecard hard reset by rpm
Reload (when linecard is in online) soft reset
Reload (when linecard is in card-problem state) hard reset by rpm
Under voltage condition power brick failed and hard reset by rpm
Command Description
hardware watchdog Enable the hardware watchdog mechanism.
Table 63-1. Line card restart causes and reasons
Causes Displayed Reasons