Reference Guide
1110 | E-Series ExaScale Debugging and Diagnostics
www.dell.com | support.dell.com
Proceed with power-off [confirm yes/no]:yes
Feb 16 00:03:19: %RPM1-P:CP %TSM-6-SFM_SWITCHFAB_STATE: Switch Fabric: DOWN
Feb 16 00:03:20: %RPM1-P:CP %CHMGR-0-MAJOR_SFM: Major alarm: Switch fabric down
FTOS#
Once the SFM is powered off, the SFM status indicates that the SFM has been powered off by the user. Use
the
show sfm all command to display the status .
FTOS#show sfm all
Switch Fabric State: down (Not enough working SFMs)
Switch Mode: SFM
-- Switch Fabric Modules --
Slot Status
---------------------------------------------------------------------------
0 power off (SFM powered off by user)
1 power off (SFM powered off by user)
2 power off (SFM powered off by user)
3 active
4 active
5 active
FTOS#
Reset the SFM
When the SFM is taken offline due to an error condition, you can execute the reset sfm command and
initiate a manual recovery.
When an error is detected on an SFM module, this command is a manual recovery mechanism. Since this
command can be used with live traffic running, the switch fabric will not go down if the switch fabric is in
an UP state. When there is a full set of SFMs online in the chassis, resetting one SFM will reduce the total
bandwidth supported by the chassis and may effect data flow. A warning message is issued at the command
line and requires user confirmation to proceed.
FTOS#reset sfm 0
SFM0 is active. Resetting it might temporarily impact data traffic.
Proceed with reset [confirm yes/no]:yes
Feb 16 00:39:30: %RPM1-P:CP %TSM-5-SFM_DISCOVERY: Found SFM 0
FTOS#
This command does not permit resetting any SFM when the system has (max-1) SFM and switch fabric is
up.
FTOS#reset sfm 1
% Error: SFM1 is active. Resetting it will impact data traffic.
FTOS#
Task Command Mode
Reset a specific SFM module (power-off and then power-on). reset sfm slot-number EXEC