Reference Guide

100 | 802.3ah
www.dell.com | support.dell.com
Frame Errors per Second
Frame Errors per Frame Period
Specify the time period for symbol
errors per second condition.
ethernet oam link-monitor symbol-period window
symbols
Range: 1-65535 (times 1,000,000 symbols)
Default: 10 (10,000,000 symbols)
INTERFACE
Task Command Syntax Command Mode
Specify the high threshold value for
frame errors, or disable the high
threshold.
ethernet oam link-monitor frame threshold high
{frames | none}
Range: 1-65535
Default: None
INTERFACE
Specify the low threshold for frame
errors.
ethernet oam link-monitor frame threshold low
frames
Range: 0-65535
Default: 1
INTERFACE
Specify the time period for frame
errors per second condition.
ethernet oam link-monitor frame window
milliseconds
Range: 10-600 milliseconds
Default: 100 milliseconds
INTERFACE
Task Command Syntax Command Mode
Specify the high threshold value for
frame errors per frame period, or
disable the high threshold.
ethernet oam link-monitor frame-period threshold
high {frames | none}
Range: 1-65535
Default: None
INTERFACE
Specify the low threshold for frame
errors per frame period.
ethernet oam link-monitor frame-period threshold
low frames
Range: 0-65535
Default: 1
INTERFACE
Specify the frame period for frame
errors per frame period condition.
ethernet oam link-monitor frame-period window
milliseconds
Range: 1-65535 (times 10,000 frames)
Default: 1000 (10 million frames)
INTERFACE
Task Command Syntax Command Mode