Users Guide
78 | Alarms
www.dell.com | support.dell.com
Power Supplies Alarms
If a Power Supply fails while the E1200i is operating, the software generates a major alarm and an SNMP
trap, and lights the major LED.
When a Power Supply fails, the software also records one alarm event for line cards, RPM, and SFM3,
though each contains its own power source. The system generates one alarm event and SNMP trap
summarizing the Power Supply failure and the components affected.
AC Power Supplies and Alarms
During system boot, if the redundant power supply (the fourth power supply) is missing or fails, the
FTOS does not generate any alarm messages since the minimum configuration of three power supplies is
operating. Yet, if a fourth AC power supply is installed, and later one of the four power supplies is
removed or fails, the system generates a minor alarm.
AC Power
Supplies
Hardware failure in a non-redundant power
configuration (3 power supplies)
major (red) major red or unlit
Hardware failure in a redundant power configuration (4
power supplies)
minor (amber) minor red or unlit
Line Card Hardware failure major (red) major amber
Exceeds high temperature limit major (red) major unlit
Exceeds warning temperature limit minor (amber) minor green
Individual interface fails minor (amber) reported amber
b
RPM (Non-redundant Configuration with 1 RPM)
Exceeds high temperature limit major (red) major unlit
Exceeds warning temperature limit minor (amber) minor green
RPM fails but CP is ok major (red) major amber
SFM3s (Redundant Configuration with 9 or 10 SFM3s)
Exceeds high temperature limit major (red) major unlit
Exceeds warning temperature limit minor (amber) minor green
Any card fails minor (amber) minor amber
Any card removed minor (amber) minor unlit
8 SFM3s (Non-Redundant Configuration)
Exceeds high temperature limit major (red) major unlit
Exceeds warning temperature limit minor (amber) minor green
Any card fails major (red) major amber
Any card removed major (red) major unlit
a. Event appears only in the show alarms command output.
b. The interface’s Link LED is unlit.
Table B-1. Alarm Events and Reporting
Module Alarm Event Alarm LED Reported in
event log
Status LED on
Module