Command Line Reference Guide
Control and Monitoring | 119
C-Series
Example
FTOS#show linecard 11
-- Line card 11 --
Status : online
Next Boot : online
Required Type : E48PF - 48-port GE line card with SFP optics (EF)
Current Type : E48PF - 48-port GE line card with SFP optics (EF)
Hardware Rev : Base - 1.0 PP0 - n/a PP1 - n/a
Num Ports : 48
Up Time : 12 hr, 37 min
FTOS Version : 6.2.1.x
Jumbo Capable : yes
Boot Flash : A: 2.0.3.4 B: 2.0.3.4 [booted]
Memory Size : 268435456 bytes
Temperature : 49C
Power Status : PEM0: absent or down PEM1: up
Voltage : ok
Serial Number :
Part Number : Rev
Vendor Id :
Date Code :
Country Code :
FTOS#
Table 7-6, "Descriptions for show linecard output," in Control and Monitoring list the definitions of the
fields shown in E-Series Example (show linecard).
Table 7-6. Descriptions for show linecard output
Field Description
Line card
Displays the line card slot number (only listed in
show linecard all command output).
Status Displays the line card’s status.
Next Boot Displays whether the line card is to be brought online at the next system reload.
Required Type Displays the line card type configured for the slot.
The Required Type and Current Type must match. Use the
linecard command to
reconfigure the line card type if they do not match.
Current Type Displays the line card type installed in the slot.
The Required Type and Current Type must match. Use the
linecard command to
reconfigure the line card type if they do not match.
Hardware Rev Displays the chip set revision.
Num Ports Displays the number of ports in the line card.
Up Time Displays the number of hours and minutes the card is online.
FTOS Version Displays the operating software version.
Jumbo Capable Displays Yes or No indicating if the line card can support Jumbo frames.
Boot Flash Ver Displays the two possible Bootflash versions. The [Booted] keyword next to the version
states which version was used at system boot.
Memory Size List the memory of the line card processor.
Temperature Displays the temperature of the line card.
Minor alarm status if temperature is over 65° C.