Reference Guide
948 | SONET/SDH
www.dell.com | support.dell.com
To view active alarms and defects, use the show controllers sonet command in EXEC Privilege mode.
When an E-Series POS or 10GE WAN interface detects a SONET alarm, a Syslog and SNMP trap
message are generated containing information about the alarm condition.
SONET TRAP Example
SONET Traps describes the traps and OIDs for SONET alarms that are reported on an SNMP trap receiver.
The following output text shows an example of a SONET trap.
2010-10-06 22:43:53 10.11.203.4 [10.11.203.4]:
SNMPv2-MIB::sysUpTime.0 = Timeticks: (6057792) 16:49:37.92
SNMPv2-MIB::snmpTrapOID.0 = OID:
SNMPv2-SMI::enterprises.6027.3.3.2.2.0.18
SNMPv2-SMI::enterprises.6027.3.3.1.2.1.1.3.0 = INTEGER: 10 SNMPv2-SMI::enter-
prises.6027.3.3.1.2.1.1.2.0 = INTEGER: 518 SNMPv2-SMI::enter-
prises.6027.3.3.1.2.1.1.4.0 = Counter32: 470351931
SNMPv2-SMI::enterprises.6027.3.3.1.2.1.1.5.0 = INTEGER: 13 SNMPv2-SMI::enter-
prises.6027.3.3.1.2.1.1.6.0 = INTEGER: 1 SNMPv2-SMI::enter-
prises.6027.3.3.1.2.1.1.7.0 = STRING: "SNMP_SONET_Alarm: Interface Te 13/1 is out of
alarm PRDI"
Task Command Syntax Command Mode
Specify which POS/SDH alarms to report
to the remote SNMP server.
alarm-report {lais | lrdi | pais | plop | prdi
|
sd-ber | sf-ber | slof | slos}
INTERFACE
Note: Historical data is not saved. The command input will show current information only.
Table 52-2. Alarm Definitions
Alarm Description
lais Line Alarm Indication Signal
lrdi Line Remote Defect Indication
pais Path Alarm Indication Signal
plop Path loss of Pointer
prdi Path Remote Defect Indication
sd-ber LBIP BER in excess of Signal Degradation threshold
sf-ber LBIP BER in excess of Signal Failure threshold
slof Section Loss of Frame
slos Section Loss of Signal