Reference Guide
Remote Monitoring | 841
Configure RMON collection statistics
To enable RMON MIB statistics collection on an interface, use the RMON collection statistics command
in interface configuration mode. To remove a specified RMON statistics collection, use the
no form of this
command.
The following command enables the RMON statistics collection on the interface, with an ID value of 20
and an owner of “john.”
FTOS(conf-if-mgmt)#rmon collection statistics controlEntry 20 owner john
Configure RMON collection history
To enable the RMON MIB history group of statistics collection on an interface, use the rmon collection
history
command in interface configuration mode. To remove a specified RMON history group of
statistics collection, use the
no form of this command.
Command Syntax Command Mode Purpose
[no] rmon collection statistics
{controlEntry integer}
[owner ownername]
CONFIGURATION
INTERFACE
(config-if)
controlEntry: Specifies the RMON group of statistics using a value.
integer: A value from 1 to 65,535 that identifies the RMON
Statistics Table. The value must be unique in the RMON
Statistic Table.
owner: (Optional) Specifies the name of the owner of the
RMON group of statistics.
ownername: (Optional) Records the name of the owner of the
RMON group of statistics. Default is a null-terminated string
Command
Syntax Command Mode Purpose
[no] rmon
collection history
{controlEntry
integer} [owner
ownername]
[buckets
bucket-number]
[interval
seconds]
CONFIGURATION
INTERFACE
(config-if)
controlEntry: Specifies the RMON group of statistics using a value.
integer: A value from 1 to 65,535 that identifies the RMON group of
statistics. The value must be a unique index in the RMON History Table.
owner: (Optional) Specifies the name of the owner of the RMON group of
statistics.Default is a null-terminated string.
ownername: (Optional) Records the name of the owner of the RMON group
of statistics.
buckets: (Optional) Specifies the maximum number of buckets desired for
the RMON collection history group of statistics.
bucket-number: (Optional) A value associated with the number of buckets
specified for the RMON collection history group of statistics. The value is
limited to from 1 to 1000. Default is 50 (as defined in RFC-2819).
interval: (Optional) Specifies the number of seconds in each polling cycle.
seconds: (Optional) The number of seconds in each polling cycle. The value
is ranged from 5 to 3,600 (Seconds). Default is 1,800 as defined in
RFC-2819.