Users Guide

1 Display the current port mode for Aggregator L2 interfaces (show interfaces switchport interface command)..
Dell#show interfaces switchport tengigabitethernet 0/1
Codes: U - Untagged, T - Tagged
x - Dot1x untagged, X - Dot1x tagged
G - GVRP tagged, M - Trunk, H - VSN tagged
i - Internal untagged, I - Internal tagged, v - VLT untagged, V - VLT tagged
Name: TenGigabitEthernet 0/1
802.1QTagged: Hybrid
SMUX port mode: Auto VLANs enabled
Vlan membership:
Q Vlans
U 1
T 2-4094
Native VlanId: 1
2 Assign the port to a specied group of VLANs (vlan tagged command) and re-display the port mode status..
Dell(conf)#interface tengigabitethernet 0/1
Dell(conf-if-te-0/1)#vlan tagged 2-5,100,4010
Dell(conf-if-te-0/1)#
Dell#show interfaces switchport tengigabitethernet 0/1
Codes: U - Untagged, T - Tagged
x - Dot1x untagged, X - Dot1x tagged
G - GVRP tagged, M - Trunk, H - VSN tagged
i - Internal untagged, I - Internal tagged, v - VLT untagged, V - VLT tagged
Name: TenGigabitEthernet 0/1
802.1QTagged: Hybrid
SMUX port mode: Admin VLANs enabled
Vlan membership:
Q Vlans
U 1
T 2-5,100,4010
Native VlanId: 1
Software show Commands
Use the show version and show system stack-unit 0 commands as a part of troubleshooting an Aggregator’s software
conguration.
Table 100. Software show Commands
Command Description
show version Display the current version of Dell Networking OS software running
on an Aggregator.
show version Command Example
Dell#show version
Dell Real Time Operating System Software
Dell Operating System Version: 2.0
Dell Application Software Version: 9-4(0-180)
Copyright (c) 1999-2014 by Dell Inc. All Rights Reserved.
Build Time: Sun Mar 30 20:15:19 PDT 2014
Build Path: /work.local/build/toolSpaces/tools05/E9-4-0/SW/SRC
Dell Networking OS uptime is 9 hour(s), 21 minute(s)
System image file is "dv-ci-stomp-tc-1-a1"
Debugging and Diagnostics
959