Setup Guide

7
Technical Specifications
The FN I/O Module is installed with the Dell PowerEdge FX2 server chassis for communication.
NOTE: Replace the battery only with same or equivalent type. Dispose of the batteries according to
the manufacturer's instructions.
Table 4. Environmental Parameters
Parameter Specifications
Operating temperature
20°C/h (36°F/h)
Storage temperature -40° to 158°F (-40° to 70°C)
Relative humidity (Storage)
5 percent to 95 percent RH with 33 °C (91 °F)
maximum dew point. Atmosphere must be non-
condensing always.
Maximum thermal output
475 BTU/hr
Maximum altitude
Operating
Storage
3048 m (10,000 ft)
12000 m (39,370 ft)
Table 5. Power Requirements
Parameter Specifications
Power supply The FN I/O Module draws power from the FX2
chassis.
Maximum current draw per system
FN410S – 5.5A @ 12V DC
FN410T – 6.5A @ 12V DC
FN2210S – 6.6A @ 12V DC
Maximum power consumption per system
FN410S – 66W
FN410T – 77W
FN2210S – 79W
Technical Specifications
13