Deployment Guide

FKA-ADV-Period 8
Fcf Priority 128
Config-State ACTIVE
Oper-State UP
Members
Fc 0/0
Te 0/14 Te 0/16
Table 104. show fcoe-map Field Descriptions
Field Description
Fabric-Name Name of a SAN fabric.
Fabric ID The ID number of the SAN fabric to which FC trac is forwarded.
VLAN ID The dedicated VLAN used to transport FCoE storage trac between servers and a fabric over
the NPG. The congured VLAN ID must be the same as the fabric ID.
VLAN priority FCoE trac uses VLAN priority 3. (This setting is not user-congurable.)
FC-MAP FCoE MAC-address prex value - The unique 24-bit MAC address prex that identies a
fabric.
FKA-ADV-period Time interval (in seconds) used to transmit FIP keepalive advertisements.
FCF Priority The priority used by a server to select an upstream FCoE forwarder.
Cong-State Indicates whether the congured FCoE and FC parameters in the FCoE map are valid: Active
(all mandatory FCoE and FC parameters are correctly congured) or Incomplete (either the
FC-MAP value, fabric ID, or VLAN ID are not correctly congured).
Oper-State Operational status of the link to the fabric: up (link is up and transmitting FC trac), down (link
is down and not transmitting FC trac), link-wait (link is up and waiting for FLOGI to complete
on peer FC port), or removed (port has been shut down).
Members FN IOM with the FC Flex IO module Ethernet and FC ports, which are members of the
dedicated FCoE VLAN that carries storage trac to the specied fabric.
show qos dcb-map Command Examples
Dell# show qos dcb-map dcbmap2
State :Complete
PfcMode:ON
--------------------
PG:0 TSA:ETS BW:50 PFC:OFF
Priorities:0 1 2 4 5 6 7
PG:1 TSA:ETS BW:50 PFC:ON
Priorities:3
FC Flex IO Modules
987