1 Decrease the maximum temperature by 1°C (1.8°F) per 300 m (985 ft.) above 900 m (2955 ft.).
2 Relative Humidity — The operating relative humidity is 8 percent to 85 percent (noncondensing) with a maximum humidity
gradation of 10 percent per hour.
Unpacking the Switch
Package Contents
When unpacking each switch, make sure that the following items are included:
One Dell Networking FN IOM module
One USB type A-to-DB-9 female cable
Getting Started Guide
Safety and Regulatory Information
Warranty and Support Information
Software License Agreement
Unpacking Steps
1 Before unpacking the switch, inspect the container and immediately report any evidence of damage.
2 Place the container on a clean, at surface and cut all straps securing the container.
3 Open the container or remove the container top.
4 Carefully remove the switch from the container and place it on a secure and clean surface.
5 Remove all packing material.
6 Inspect the product and accessories for damage.
After you insert a Flex IO module into an empty slot, you must reload the FN IOM for the module. If you remove an installed module and
insert a dierent module type, an error message displays to remind you that the slot is congured for a dierent type of Flex IO module. You
must reload the switch to make the Flex IO module operational.
Interconnectivity of FC Flex IO Modules with Cisco MDS
Switches
In a network topology that contains Cisco MDS switches, FC Flex IO modules that are plugged into the FN IOM switches enable
interoperation for a robust, eective deployment of the NPIV proxy gateway and FCoE-FC bridging behavior. In an environment that
contains FC Flex IO modules and Cisco MDS switches, perform the following steps:
Insert the FC Flex IO module into any of the optional module slots of the FN IOM Switch and reload the switch.
When the device is reloaded, NPIV mode is automatically enabled.
Congure the NPIV-related commands on FN IOM.
After you perform the preceding procedure, the following operations take place:
A physical link is established between the FC Flex I/O module and the Cisco MDS switch.
The FC Flex I/O module sends a proxy FLOGI request to the upstream F_Port of the FC switch or the MDS switch. The F_port
accepts the proxy FLOGI request for the FC Flex IO virtual N_Port. The converged network adapters (CNAs) are brought online and
the FIP application is run.
Discovery of the VLAN and FCF MAC addresses is completed.
944
FC Flex IO Modules