Deployment Guide
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2
-------------------------------
0 55 45 58
Dell#
Recognize an Under-Voltage Condition
If the system detects an under-voltage condition, it sends an alarm.
To recognize this condition, look for the following system message: %CHMGR-1-CARD_SHUTDOWN: Major alarm: Line card 2
down - auto-shutdown due to under voltage.
This message indicates that the specied card is not receiving enough power. In response, the system rst shuts down Power over
Ethernet (PoE).
Troubleshoot an Under-Voltage Condition
To troubleshoot an under-voltage condition, check that the correct number of power supplies are installed and their Status light emitting
diodes (LEDs) are lit.
The following table lists information for SNMP traps and OIDs, which provide information about environmental monitoring hardware and
hardware components.
Table 92. SNMP Traps and OIDs
OID String OID Name Description
Receiving Power
.1.3.6.1.4.1.6027.3.10.1.2.5.1.6 chSysPortXfpRecvPower OID displays the receiving power of the
connected optics.
Transmitting power
.1.3.6.1.4.1.6027.3.10.1.2.5.1.8 chSysPortXfpTxPower OID displays the transmitting power of the
connected optics.
Temperature
.1.3.6.1.4.1.6027.3.10.1.2.5.1.7 chSysPortXfpRecvTemp OID displays the temperature of the
connected optics.
NOTE: These OIDs only generate if
you enable the enable optic-
info-update-interval is
enabled command.
Hardware MIB Buer Statistics
.1.3.6.1.4.1.6027.3.27.1.4 dellNetFpPacketBuerTable View the modular packet buers details per
stack unit and the mode of allocation.
.1.3.6.1.4.1.6027.3.27.1.5 dellNetFpStatsPerPortTable View the forwarding plane statistics
containing the packet buer usage per port
per stack unit.
.1.3.6.1.4.1.6027.3.27.1.6 dellNetFpStatsPerCOSTable View the forwarding plane statistics
containing the packet buer statistics per
COS per port.
926 Debugging and Diagnostics