Deployment Guide

Table 86. show npiv devices Field Descriptions
Field Description
ENode [number] Server CNA that has successfully logged in to a fabric over an Aggregator with the Ethernet
port in ENode mode.
Enode MAC MAC address of a server CNA port.
Enode Intf Port number of a server-facing Ethernet port operating in ENode mode.
FCF MAC Fibre Channel forwarder MAC: MAC address of Aggregator with the FCF interface.
Fabric Intf Fabric-facing Aggregator with the Fibre Channel port (slot/port) on which FCoE trac is
transmitted to the specied fabric.
FCoE VLAN ID of the dedicated VLAN used to transmit FCoE trac from a server CNA to a fabric and
congured on both the server-facing Aggregator with the server CNA port.
Fabric Map Name of the FCoE map containing the FCoE/FC conguration parameters for the server
CNA-fabric connection.
Enode WWPN Worldwide port name of the server CNA port.
Enode WWNN Worldwide node name of the server CNA.
FCoE MAC Fabric-provided MAC address (FPMA). The FPMA consists of the FC-MAP value in the FCoE
map and the FC-ID provided by the fabric after a successful FLOGI. In the FPMA, the most
signicant bytes are the FC-MAP; the least signicant bytes are the FC-ID.
FC-ID FC port ID provided by the fabric.
LoginMethod Method used by the server CNA to log in to the fabric; for example, FLOGI or FDISC.
Secs Number of seconds that the fabric connection is up.
State Status of the fabric connection: logged in.
show fc switch Command Example
Dell# show fc switch
Switch Mode : NPG
Switch WWN : 10:00:5c:f9:dd:ef:10:c0
Dell#
Table 87. show fc switch Command Description
Field Description
Switch Mode Fibre Channel mode of operation of an Aggregator. Default: NPG (congured as an NPIV proxy
gateway).
Switch WWN Factory-assigned worldwide node (WWN) name of the Aggregator. The Aggregator WWN
name is not user-congurable.
852 NPIV Proxy Gateway