Deployment Guide
Speed Transmission speed (in Megabits per second) of Ethernet and FC ports, including auto-
negotiated speed (Auto).
Duplex Data transmission mode: Full (allows communication in both directions at the same time), Half
(allows communication in both directions but not at the same time), Auto (auto-negotiated
transmission).
VLAN VLAN IDs of the VLANs in which the port is a member.
show fcoe-map Command Examples
Dell# show fcoe-map brief
Fabric-Name Fabric-Id Vlan-Id FC-MAP FCF-Priority Config-State Oper-State
fid_1003 1003 1003 0efc03 128 ACTIVE UP
fid_1004 1004 1004 0efc04 128 ACTIVE DOWN
Dell# show fcoe-map fid_1003
Fabric Name fid_1003
Fabric Id 1003
Vlan Id 1003
Vlan priority 3
FC-MAP 0efc03
FKA-ADV-Period 8
Fcf Priority 128
Config-State ACTIVE
Oper-State UP
Members
Fc 0/9
Te 0/11 Te 0/12
Table 83. show fcoe-map Field Descriptions
Field Description
Fabric-Name Name of a SAN fabric.
Fabric ID The ID number of the SAN fabric to which FC trac is forwarded.
VLAN ID The dedicated VLAN used to transport FCoE storage trac between servers and a fabric over
the NPG. The congured VLAN ID must be the same as the fabric ID.
VLAN priority FCoE trac uses VLAN priority 3. This setting is not user-congurable.
FC-MAP FCoE MAC-address prex value - The unique 24-bit MAC address prex that identies a
fabric.
FKA-ADV-period Time interval (in seconds) used to transmit FIP keepalive advertisements.
FCF Priority The priority used by a server to select an upstream FCoE forwarder.
Cong-State Indicates whether the congured FCoE and FC parameters in the FCoE map are valid: Active
(all mandatory FCoE and FC parameters are correctly congured) or Incomplete (either the
FC-MAP value, fabric ID, or VLAN ID are not correctly congured).
NPIV Proxy Gateway 849