Deployment Guide

Dell(config-dcbx-name)# priority-group 2 bandwidth 20 pfc on
Dell(config-dcbx-name)# priority-group 4 strict-priority pfc off
Dell(conf-dcbx-name)# priority-pgid 0 0 0 1 2 4 4 4
2 Apply the DCB map on a downstream (server-facing) Ethernet port:
Dell(config)# interface tengigabitethernet 0/1
Dell(config-if-te-0/0)#dcb-map SAN_DCB_MAP
3 Create the dedicated VLAN to be used for FCoE trac:
Dell(conf)#interface vlan 1002
4 Congure an FCoE map to be applied on downstream (server-facing) Ethernet and upstream (core-facing) FC ports:
Dell(config)# fcoe-map SAN_FABRIC_A
Dell(config-fcoe-name)# fabric-id 1002 vlan 1002
Dell(config-fcoe-name)# description "SAN_FABRIC_A"
Dell(config-fcoe-name)# fc-map 0efc00
Dell(config-fcoe-name)# keepalive
Dell(config-fcoe-name)# fcf-priority 128
Dell(config-fcoe-name)# fka-adv-period 8
5 Enable an upstream FC port:
Dell(config)# interface fibrechannel 0/9
Dell(config-if-fc-0)# no shutdown
6 Enable a downstream Ethernet port:
Dell(config)#interface tengigabitEthernet 0/1
Dell(conf-if-te-0)# no shutdown
Displaying NPIV Proxy Gateway Information
To display information on the NPG operation, use the show commands in the following table:
Table 81. Displaying NPIV Proxy Gateway Information
Command Description
show interfaces status
Displays the operational status of Ethernet and Fibre Channel interfaces on the
Aggregator with the NPG.
NPIV Proxy Gateway 847