Deployment Guide
Term Description
N port Port mode of an Aggregator with the FC port that connects to an F port on an FC switch in a
SAN fabric. On an Aggregator with the NPIV proxy gateway, an N port also functions as a proxy
for multiple server CNA-port connections.
ENode port Port mode of a server-facing Aggregator with the Ethernet port that provides access to FCF
functionality on a fabric.
CNA port N-port functionality on an FCoE-enabled server port. A converged network adapter (CNA) can
use one or more Ethernet ports. CNAs can encapsulate Fibre Channel frames in Ethernet for
FCoE transport and de-encapsulate Fibre Channel frames from FCoE to native Fibre Channel.
DCB map Template used to congure DCB parameters, including priority-based ow control (PFC) and
enhanced transmission selection (ETS), on CEE ports.
Fibre Channel fabric Network of Fibre Channel devices and storage arrays that inter-operate and communicate.
FCF Fibre Channel forwarder: FCoE-enabled switch that can forward FC trac to both downstream
FCoE and upstream FC devices. An NPIV proxy gateway functions as an FCF to export
upstream F port congurations to downstream server CNA ports.
FC-MAP FCoE MAC-address prex — The unique 24-bit MAC address prex in FCoE packets used to
generate a fabric-provided MAC address (FPMA). The FPMA is required to send FCoE packets
from a server to a SAN fabric.
FCoE map Template used to congure FCoE and FC parameters on Ethernet and FC ports in a converged
fabric.
FCoE VLAN VLAN dedicated to carrying only FCoE trac between server CNA ports and a SAN fabric.
(FCoE trac must travel in a VLAN.) When you apply an FCoE map on a port, FCoE is enabled
on the port. All non-FCoE trac is dropped on an FCoE VLAN.
FIP FCoE Initialization Protocol: Layer 2 protocol for endpoint discovery, fabric login, and fabric
association. FIP is used by server CNAs to discover an upstream FCoE switch operating as an
FCF. FIP keepalive messages maintain the connection between an FCoE initiator and an FCF.
NPIV N-port identier virtualization: The capability to map multiple FCoE links from downstream ports
to a single upstream FC link.
principal switch The switch in a fabric with the lowest domain number. The principal switch accesses the master
name database and the zone/zone set database.
DCB Maps
A Data Center Bridging (DCB) map is used to congure DCB functionality, such as PFC and ETS, on the Aggregator with the Ethernet
ports that support CEE trac and are DCBx-enabled, by default.
By default, no PFC and ETS settings in a DCB map are applied to the Aggregator with the Ethernet ports when they are enabled. On an
Aggregator with the NPG, you must congure PFC and ETS parameters in a DCB map and then apply the map to server-facing Ethernet
ports.
FCoE Maps
An FCoE map is used to identify the SAN fabric to which FCoE storage trac is sent. Using an FCoE map, an Aggregator with the NPG
operates as an FCoE-FC bridge between an FC SAN and FCoE network by providing FCoE-enabled servers and switches with the
necessary parameters to log in to a SAN fabric.
840
NPIV Proxy Gateway