Deployment Guide

The delay-restore feature waits for all saved congurations to be applied, then starts a congurable timer. After the timer expires, the
VLT ports are enabled one-by-one in a controlled manner. The delay between bringing up each VLT port-channel is proportional to the
number of physical members in the port-channel. The default is 90 seconds.
If you enable IGMP snooping, IGMP queries are also sent out on the VLT ports at this time allowing any receivers to respond to the queries
and update the multicast table on the new node.
This delay in bringing up the VLT ports also applies when the VLTi link recovers from a failure that caused the VLT ports on the secondary
VLT peer node to be disabled.
Non-VLT ARP Sync
In the Dell Networking OS version 9.2(0.0), ARP entries (including ND entries) learned on other ports are synced with the VLT peer to
support station move scenarios.
Prior to Dell Networking OS version 9.2.(0.0), only ARP entries learned on VLT ports were synced between peers.
Additionally, ARP entries resulting from station movements from VLT to non-VLT ports or to dierent non-VLT ports are learned on the
non-VLT port and synced with the peer node. The peer node is updated to use the new non-VLT port.
NOTE: ARP entries learned on non-VLT, non-spanned VLANs are not synced with VLT peers.
Verifying a VLT Conguration
To monitor the operation or verify the conguration of a VLT domain, use any of the following show commands on the primary and
secondary VLT switches.
Display information on backup link operation.
EXEC mode
show vlt backup-link
Display general status information about VLT domains currently congured on the switch.
EXEC mode
show vlt brief
Display detailed information about the VLT-domain conguration, including local and peer port-channel IDs, local VLT switch status, and
number of active VLANs on each port channel.
EXEC mode
show vlt detail
Display the VLT peer status, role of the local VLT switch, VLT system MAC address and system priority, and the MAC address and
priority of the locally-attached VLT device.
EXEC mode
show vlt role
Display the current conguration of all VLT domains or a specied group on the switch.
EXEC mode
show running-config vlt
Display statistics on VLT operation.
EXEC mode
show vlt statistics
Display the current status of a port or port-channel interface used in the VLT domain.
EXEC mode
PMUX Mode of the IO Aggregator
831