Deployment Guide

Standalone mode is the zero-touch auto conguration default mode. If you want the exibility to congure dierent settings, change the
FN I/O Module to PMUX mode. PMUX mode provides additional CLI commands to customize the software conguration, as needed.
You can congure any of the external Ethernet ports to operate as stack links.
For more information on the PMUX mode, see PMUX Mode of the IO Aggregator.
Stacking mode
stack-unit unit iom-mode stack
CONFIGURATION mode
Dell(conf)#stack-unit 0 iom-mode stack
Select this mode to congure Stacking mode CLI commands.
The lower two external Ethernet ports (ports 9 and 10) operate as stack links.
For more information on the Stacking mode, see .
Full Switch mode
stack-unit unit iom-mode full-switch
CONFIGURATION mode
Dell(conf)#stack-unit 0 iom-mode full-switch
Select this mode to congure full switch CLI commands. Full-Switch mode oers Layer 2 or Layer 3 switching functionalities on the Dell
FX2 chassis.
For more information on the Full Switch mode, see Dell Networking OS Command Line Reference Guide.
Default Settings
The I/O Aggregator provides zero-touch conguration with the following default conguration settings:
default user name (root)
password (calvin)
VLAN (vlan1) and IP address for in-band management (DHCP)
IP address for out-of-band (OOB) management (DHCP)
read-only SNMP community name (public)
broadcast storm control (enabled in Standalone mode and disabled in VLT mode)
IGMP multicast ooding (enabled)
VLAN conguration (in Standalone mode, all ports belong to all VLANs)
You can change any of these default settings using the CLI. Refer to the appropriate chapter for details.
NOTE
: You can also change many of the default settings using the chassis management controller (CMC) interface. For
information about how to access the CMC to congure the aggregator, refer to the
Dell Chassis Management Controller (CMC)
User’s Guide
on the Dell Support website at http://support.dell.com/
Before You Start 35