Deployment Guide
Figure 35. FIP Snooping on an FN IOMSwitch Conguration Example
• A server-facing port is congured for DCBx in an auto-downstream role.
• An FCF-facing port is congured for DCBx in an auto-upstream or conguration-source role.
The DCBx conguration on the FCF-facing port is detected by the server-facing port and the DCB PFC conguration on both ports is
synchronized. For more information about how to congure DCBx and PFC on a port, refer to the Data Center Bridging (DCB) chapter.
The following example shows how to congure FIP snooping on FCoE VLAN 10, on an FCF-facing port (0/50), on an ENode server-facing
port (0/1), and to congure the FIP snooping ports as tagged members of the FCoE VLAN enabled for FIP snooping.
Example of Enabling the FIP Snooping Feature on the Switch (FIP Snooping Bridge)
Dell(conf)# feature fip-snooping
Example of Enabling FIP Snooping on the FCoE VLAN
Dell(conf)# interface vlan 10
Dell(conf-if-vl-10)# fip-snooping enable
Example of Enabling an FC-MAP Value on a VLAN
Dell(conf-if-vl-10)# fip-snooping fc-map 0xOEFC01
FCoE Transit
303