Deployment Guide

Figure 35. FIP Snooping on an FN IOMSwitch Conguration Example
A server-facing port is congured for DCBx in an auto-downstream role.
An FCF-facing port is congured for DCBx in an auto-upstream or conguration-source role.
The DCBx conguration on the FCF-facing port is detected by the server-facing port and the DCB PFC conguration on both ports is
synchronized. For more information about how to congure DCBx and PFC on a port, refer to the Data Center Bridging (DCB) chapter.
The following example shows how to congure FIP snooping on FCoE VLAN 10, on an FCF-facing port (0/50), on an ENode server-facing
port (0/1), and to congure the FIP snooping ports as tagged members of the FCoE VLAN enabled for FIP snooping.
Example of Enabling the FIP Snooping Feature on the Switch (FIP Snooping Bridge)
Dell(conf)# feature fip-snooping
Example of Enabling FIP Snooping on the FCoE VLAN
Dell(conf)# interface vlan 10
Dell(conf-if-vl-10)# fip-snooping enable
Example of Enabling an FC-MAP Value on a VLAN
Dell(conf-if-vl-10)# fip-snooping fc-map 0xOEFC01
FCoE Transit
303