Deployment Guide
FC FPORT
FC FPort can be congured on ports 9 and 10 of Combo port card in Dell FX2 chassis.
Conguring Switch Mode to FCF Port Mode
To congure switch mode to Fabric services, use the following commands.
1 Congure Switch mode to FCF Port.
CONFIGURATION mode
feature fc fport domain id 2
NOTE
: Enable remote-fault-signaling rx off command in FCF FPort mode on interfaces connected to the
Compellent and MDF storage devices.
2 Create an FCoE map with the parameters used in the communication between servers and a SAN fabric.
CONFIGURATION mode
282
FC FPORT