Concept Guide
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.6(0.0) Supported on the FN 2210S Aggregator.
9.4(0.0) Supported on the FN I/O Aggregator.
9.3(0.0) Supported on the M I/O Aggregator.
Example
Dell#show interface status
Port Description Status Speed Duplex Vlan
Te 0/1 Up 10000 Mbit Full 1-4094
Te 0/2 Up 10000 Mbit Full 1-4094
Te 0/3 Up 10000 Mbit Full 1-4094
Te 0/4 Up 10000 Mbit Full 1-4094
Te 0/5 Up 10000 Mbit Full --
Te 0/6 Up 10000 Mbit Full 1-4094
Te 0/7 Up 10000 Mbit Full --
Te 0/8 Up 10000 Mbit Full --
Te 0/9 Up 10000 Mbit Full --
Te 0/10 Up 10000 Mbit Full --
Te 0/11 Up 10000 Mbit Full --
Te 0/12 Up 10000 Mbit Full --
Dell#
show npiv devices
Displays the FCoE and FC devices currently logged into an FN I/O Aggregator Switch with the FC Flex IO module NPIV proxy gateway.
Syntax
show npiv devices [brief]
Parameters
brief Displays an overview of current server CNA-fabric connections over an FN I/O
Aggregator with the FC Flex IO module NPIV proxy gateway.
Command Modes
• EXEC
• EXEC Privilege
Supported Modes All modes
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.6.(0.0) Supported on the FN2210S Aggregator.
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO
module.
Usage Information
Use the show npiv devices command to display information on the server CNA, server-facing Ethernet and
fabric-facing FC ports, and the SAN fabric in each server-fabric connection over an FN I/O Aggregator with the
FC Flex IO module NPIV proxy gateway.
The following describes the show npiv devices brief output shown in the example.
NPIV Proxy Gateway 913