CLI Guide
To disable optical power information updates, use the no enable optical-
info-update interval command.
Parameters
interval seconds Enter the keyword interval then the polling interval in
seconds. The range is from 120 to 6000 seconds. The
default is 300 seconds (5 minutes).
Defaults Disabled
Command Modes CONFIGURATION
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Replaces the enable xfp-power-updates command.
Usage Information To enable polling and to configure the polling frequency, use this command.
enable secure
Creates configurable Full–Switch mode where Chassis Management Controller (CMC) access to FN IOM
is bypassed for the elements critical to the security certifications.
Syntax
enable secure
To disable the secure mode, use no enable secure command.
Parameters None
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.7(0.0) Introduced on the MXL.
end
Return to EXEC Privilege mode from other command modes (for example, CONFIGURATION mode).
Syntax
end
Command Modes
• CONFIGURATION
Control and Monitoring