CLI Guide
Port Type Node port
Registered with NameServer No
Registered for SCN No
Switch Name 10:00:5c:f9:dd:ef:0a:00
Domain Id 1
Switch Port 53
Port Id 01:35:00
Port Name 10:00:8c:7c:ff:17:f8:01
Node Name 20:00:8c:7c:ff:17:f8:01
Class of Service 8
IP Address
Symbolic Port Name Brocade-1860 | 3.0.3.0 | DV-SP-
SERVER2 | |
Symbolic Node Name (NULL)
Port Type Node port
Registered with NameServer Yes
Registered for SCN Yes
Dell#
Dell#show fc ns fabric brief
Total number of devices = 2
Intf# Domain FC-ID Enode-
WWPN Enode-WWNN
9 2 02:09:00 32:11:0e:fc:00:00:00:88
22:11:0e:fc:00:00:00:88
11 2 02:0b:00 31:11:0e:fc:00:00:00:77
21:11:0e:fc:00:00:00:77
Dell#
show fc switch
Display the switch configuration for Fibre Channel capability.
Syntax
show fc switch
Parameters None
Command Modes
• EXEC
• EXEC Privilege
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.7(0.0) Introduced on the MXL 10/40GbE Switch IO Module.
9.0(1.3) Introduced on the S5000.
Usage Information
The following table describes the show fc switch output shown in the following
example.
FC FLEXIO FPORT
557