CLI Guide
bfd disable
Disable BFD on an interface.
Syntax
bfd disable
Re-enable BFD using the no bfd disable command.
Defaults BFD is disabled by default.
Command Modes INTERFACE VRRP
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.2(0.0) Introduced on the MXL 10/40GbE Switch IO Module.
bfd enable (Configuration)
Enable BFD on all interfaces.
Syntax
bfd enable
Disable BFD using the no bfd enable command.
Defaults BFD is disabled by default.
Command Modes CONFIGURATION
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.2(0.0) Introduced on the MXL 10/40GbE Switch IO Module.
bfd enable (Interface)
Enable BFD on an interface.
Syntax
bfd enable
Defaults BFD is enabled on all interfaces when you enable BFD from CONFIGURATION
mode.
Command Modes INTERFACE
328
Bidirectional Forwarding Detection (BFD)