CLI Guide

Command Modes FCOE MAP
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE
Switch with the FC Flex IO module.
Usage Information
In the fabric-id vlan command, the fabric and VLAN ID numbers must be the
same.
In each FCoE map, the fabric ID, FC-MAP value, and FCoE VLAN parameters must
be unique.
To remove a fabric-VLAN association from an FCoE map, enter the no fabric-id
vlan command.
You must first create a VLAN and then specify the configured VLAN ID in the
fabric-id vlan command. Otherwise, the following error message is displayed.
FTOS(conf-fcoe-f)#fabric-id 10 vlan 10 % Error: Vlan 10 does
not exist
Related
Commands
fcoe-map — creates an FCoE map which contains the parameters used in the
communication between servers and a SAN fabric.
show fcoe-map — displays the Fibre Channel and FCoE configuration parameters
in FCoE maps.
fcf-priority
In an FCoE map, configure the priority used by a server CNA to select an upstream FCoE forwarder (FCF).
Syntax
fcf—priority priority
Parameters
priority Enter the priority assigned to the switch with the FC Flex IO
module NPIV proxy gateway, which appears to a
downstream server CNA as an FCF. The range of FCF
priority values is from 1 to 255.
Defaults 128
Command Modes FCOE MAP
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
1562
FC Flex IO Modules