CLI Guide

Auto Data Sync: Full
Failover Type: Hot Failover
Auto reboot Stack-unit: Enabled
Auto failover limit: 3 times in 60 minutes
-- Stack-unit Failover Record --
------------------------------------------------
Failover Count: 0
Last failover timestamp: None
Last failover Reason: None
Last failover type: None
-- Last Data Block Sync Record: --
------------------------------------------------
Stack Unit Config: no block sync done
Start-up Config: no block sync done
Runtime Event Log: no block sync done
Running Config: no block sync done
ACL Mgr: no block sync done
LACP: no block sync done
STP: no block sync done
SPAN: no block sync done
Dell#
Related
Commands
redundancy disable-auto-reboot — prevents the system from auto-rebooting if it
fails.
show system stack-ports
Display information about the stacking ports on all switches in the FN I/O Aggregator switch stack..
Syntax
show system stack-ports [status | topology]
Parameters
status (OPTIONAL) Enter the keyword status to display the
command output without the Connection field.
topology (OPTIONAL) Enter the keyword topology to limit the table
to just the Interface and Connection fields.
Defaults none
Command Modes
EXEC
EXEC Privilege
Supported Modes All Modes
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.6.(0.0) Supported on the FN I/O Aggregator.
1432