CLI Guide
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
---------------------------------------------------------------------------------
---
0 Management online I/O-Aggregator I/O-Aggregator 8-3-17-46 56
1 Standby online I/O-Aggregator I/O-Aggregator 8-3-17-46 56
2 Member not present
3 Member not present
4 Member not present
5 Member not present
Dell#
Dell#reset stack-unit 0 >>>Resetting master not allowed
% Error: Reset of master unit is not allowed.
Dell#
Dell#reset stack-unit 1
Dell#01:02:00: %STKUNIT0-M:CP %CHMGR-5-STACKUNIT_RESET: Stack unit 1 being reset
01:02:00: %STKUNIT0-M:CP %IFMGR-1-DEL_PORT: Removed port: Te 1/1-32,41-56
01:02:00: %STKUNIT0-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 1 down - reset
01:02:00: %STKUNIT1-S:CP %IFMGR-1-DEL_PORT: Removed port: Te 1/1-32,41-56
01:02:05: %I/O-Aggregator:0 %IFAGT-5-STACK_PORT_LINK_DOWN: Changed stack port
state to down: 0/10
01:02:11: %STKUNIT0-M:CP %POLLMGR-2-ALT_STACK_UNIT_STATE: Alternate Stack-unit is
not present
Dell#01:02:12: %STKUNIT0-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 1 down - card
removed
Related
Commands
reload— reboots the system.
show redundancy
Display the current redundancy configuration (status of automatic reboot configuration on stack
management unit).
Syntax
show redundancy
Command Modes
• EXEC
• EXEC Privilege
Supported Modes Full–Switch Mode
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Example
Dell#show redundancy
-- Stack-unit Status --
------------------------------------------------
Mgmt ID: 0
Stack-unit ID: 0
Stack-unit Redundancy Role: Primary
Stack-unit State: Active
Stack-unit SW Version: E8-3-16-160
Link to Peer: Down
Peer Stack-unit: not present
-- Stack-unit Redundancy Configuration --
------------------------------------------------
Primary Stack-unit: mgmt-id 0
Stacking Commands
1431