CLI Guide
Version Description
8.3.17.0 Supported on the M I/O Aggregator.
Usage Information
This command is supported on the M I/O, FN410S, and FN410T Aggregators.
This command is used to reset the stack-unit. The master unit can also be power
cycled using this command.
redundancy disable-auto-reboot
Prevent the switch stack management unit from rebooting if it fail.
Syntax
redundancy disable-auto-reboot stack-unit [0–5 | members]
To return to the default, use the no redundancy disable-auto-reboot
stack-unit [0–5 | members] command.
Defaults Disabled (the failed switch is automatically rebooted).
Command Modes CONFIGURATION
Supported Modes Full–Switch Mode
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information
When the command is given as redundancy disable-auto-reboot stack-
unit, it prevents the switch stack management unit and standby unit from
rebooting if they fail.
When a particular unit number in the range from 0 to 5 is issued as part of the CLI,
it prevents that particular unit from rebooting after failure.
When members are issued as part of the CLI, all the units part of the stack are
prevented from rebooting after failure.
The unit does not reboot until it is manually rebooted.
Related
Commands
show redundancy — displays the current redundancy status.
Stacking Commands
1429