CLI Guide
Te 0/1: configured rate 256, actual rate 256
Dell#
Dell#show running-config sflow
!
sflow enable
sflow sample-rate 2048
Dell#show running-config interface tengigabitethernet 0/1
!
interface TenGigabitEthernet 0/1
no ip address
sflow enable
sflow sample-rate 256
no shutdown
show sflow stack-unit
Display the sFlow information on a stack unit.
Syntax
show sflow stack-unit {unit number}
Parameters
unit number (OPTIONAL) Enter a unit number to view information on the
stack unit in that slot. The range is from 0 to 5.
Command Modes
• EXEC
• EXEC Privilege
Supported Modes Full–Switch Mode
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information
The dropEvent counter (sFlow samples dropped due to sub-sampling) shown in
the following example below always displays a value of zero.
Example
Dell#show sflow stack-unit 1
Stack-Unit 1
Samples rcvd from h/w :0
Total UDP packets exported :0
UDP packets dropped :0
Dell#
sFlow
1385